Review




Structured Review

Ciphergen inc immobilized cu proteinchip array imac30
Immobilized Cu Proteinchip Array Imac30, supplied by Ciphergen inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/immobilized cu proteinchip array imac30/product/Ciphergen inc
Average 90 stars, based on 1 article reviews
immobilized cu proteinchip array imac30 - by Bioz Stars, 2026-02
90/100 stars

Images



Similar Products

90
Ciphergen inc immobilized cu proteinchip array imac30
Immobilized Cu Proteinchip Array Imac30, supplied by Ciphergen inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/immobilized cu proteinchip array imac30/product/Ciphergen inc
Average 90 stars, based on 1 article reviews
immobilized cu proteinchip array imac30 - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Ciphergen inc proteinchip array, imac30-cu 2+ (immobilized metal affinity chromatography, ph7
Proteomic analyses demonstrating the differences in protein profiles of sera from diabetic and wild-type mice. Serum samples from fasting diabetic (db+/db+) mice and fasting wild-type (+m/+m) mice were loaded onto ProteinChip arrays. (A) List of peaks of proteins and/or peptides with indicated m/z values, the peak intensities of which were significantly changed in the diabetic state. Relative peak intensities were averaged (n = 8). The fold changes are presented as ratios of the peak intensities at indicated m/z values in db+/db+ to those in the +m/+m mice. Peaks at m/z 4203, 4576, 8515, 9291, 17406 and 18678 were obtained using CM10 ProteinChip (pH4). Peaks at 8733 and 9311 m/z were obtained using CM10 ProteinChip <t>(pH7).</t> Peaks at m/z 3933, 4119, 4206, 4369, 4566, 4579, 4637, 8523, 8827, 8915, 9283, 13075, 17407, 17418, 17622, 18431, 18691, 22334 and 26100 were obtained using Q10 ProteinChip. Peak at m/z 4211 was obtained using <t>IMAC30.</t> The chips were analyzed by SELDI-TOF-MS. (B) and (C) Typical data of relative peak intensities in +m/+m and db+/db+ mouse sera (upper, representative of 4–8 independent observations) and the peak intensity averages at m/z 4206 and 26100 (lower, n = 4 for +m/+m, n = 8 for db+/db+). The analyzed peak is indicated by arrows in the data of mass spectral signals. **P < 0.01; significantly different from the peak in wild-type mice, by unpaired t -test.
Proteinchip Array, Imac30 Cu 2+ (Immobilized Metal Affinity Chromatography, Ph7, supplied by Ciphergen inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/proteinchip array, imac30-cu 2+ (immobilized metal affinity chromatography, ph7/product/Ciphergen inc
Average 90 stars, based on 1 article reviews
proteinchip array, imac30-cu 2+ (immobilized metal affinity chromatography, ph7 - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Ciphergen inc immobilized cu proteinchip array
Proteomic analyses demonstrating the differences in protein profiles of sera from diabetic and wild-type mice. Serum samples from fasting diabetic (db+/db+) mice and fasting wild-type (+m/+m) mice were loaded onto ProteinChip arrays. (A) List of peaks of proteins and/or peptides with indicated m/z values, the peak intensities of which were significantly changed in the diabetic state. Relative peak intensities were averaged (n = 8). The fold changes are presented as ratios of the peak intensities at indicated m/z values in db+/db+ to those in the +m/+m mice. Peaks at m/z 4203, 4576, 8515, 9291, 17406 and 18678 were obtained using CM10 ProteinChip (pH4). Peaks at 8733 and 9311 m/z were obtained using CM10 ProteinChip <t>(pH7).</t> Peaks at m/z 3933, 4119, 4206, 4369, 4566, 4579, 4637, 8523, 8827, 8915, 9283, 13075, 17407, 17418, 17622, 18431, 18691, 22334 and 26100 were obtained using Q10 ProteinChip. Peak at m/z 4211 was obtained using <t>IMAC30.</t> The chips were analyzed by SELDI-TOF-MS. (B) and (C) Typical data of relative peak intensities in +m/+m and db+/db+ mouse sera (upper, representative of 4–8 independent observations) and the peak intensity averages at m/z 4206 and 26100 (lower, n = 4 for +m/+m, n = 8 for db+/db+). The analyzed peak is indicated by arrows in the data of mass spectral signals. **P < 0.01; significantly different from the peak in wild-type mice, by unpaired t -test.
Immobilized Cu Proteinchip Array, supplied by Ciphergen inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/immobilized cu proteinchip array/product/Ciphergen inc
Average 90 stars, based on 1 article reviews
immobilized cu proteinchip array - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Ciphergen inc copper (ii) immobilized metal affinity capture (imac3-cu [ii]) proteinchip® array
Proteomic analyses demonstrating the differences in protein profiles of sera from diabetic and wild-type mice. Serum samples from fasting diabetic (db+/db+) mice and fasting wild-type (+m/+m) mice were loaded onto ProteinChip arrays. (A) List of peaks of proteins and/or peptides with indicated m/z values, the peak intensities of which were significantly changed in the diabetic state. Relative peak intensities were averaged (n = 8). The fold changes are presented as ratios of the peak intensities at indicated m/z values in db+/db+ to those in the +m/+m mice. Peaks at m/z 4203, 4576, 8515, 9291, 17406 and 18678 were obtained using CM10 ProteinChip (pH4). Peaks at 8733 and 9311 m/z were obtained using CM10 ProteinChip <t>(pH7).</t> Peaks at m/z 3933, 4119, 4206, 4369, 4566, 4579, 4637, 8523, 8827, 8915, 9283, 13075, 17407, 17418, 17622, 18431, 18691, 22334 and 26100 were obtained using Q10 ProteinChip. Peak at m/z 4211 was obtained using <t>IMAC30.</t> The chips were analyzed by SELDI-TOF-MS. (B) and (C) Typical data of relative peak intensities in +m/+m and db+/db+ mouse sera (upper, representative of 4–8 independent observations) and the peak intensity averages at m/z 4206 and 26100 (lower, n = 4 for +m/+m, n = 8 for db+/db+). The analyzed peak is indicated by arrows in the data of mass spectral signals. **P < 0.01; significantly different from the peak in wild-type mice, by unpaired t -test.
Copper (Ii) Immobilized Metal Affinity Capture (Imac3 Cu [Ii]) Proteinchip® Array, supplied by Ciphergen inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/copper (ii) immobilized metal affinity capture (imac3-cu [ii]) proteinchip® array/product/Ciphergen inc
Average 90 stars, based on 1 article reviews
copper (ii) immobilized metal affinity capture (imac3-cu [ii]) proteinchip® array - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

Image Search Results


Proteomic analyses demonstrating the differences in protein profiles of sera from diabetic and wild-type mice. Serum samples from fasting diabetic (db+/db+) mice and fasting wild-type (+m/+m) mice were loaded onto ProteinChip arrays. (A) List of peaks of proteins and/or peptides with indicated m/z values, the peak intensities of which were significantly changed in the diabetic state. Relative peak intensities were averaged (n = 8). The fold changes are presented as ratios of the peak intensities at indicated m/z values in db+/db+ to those in the +m/+m mice. Peaks at m/z 4203, 4576, 8515, 9291, 17406 and 18678 were obtained using CM10 ProteinChip (pH4). Peaks at 8733 and 9311 m/z were obtained using CM10 ProteinChip (pH7). Peaks at m/z 3933, 4119, 4206, 4369, 4566, 4579, 4637, 8523, 8827, 8915, 9283, 13075, 17407, 17418, 17622, 18431, 18691, 22334 and 26100 were obtained using Q10 ProteinChip. Peak at m/z 4211 was obtained using IMAC30. The chips were analyzed by SELDI-TOF-MS. (B) and (C) Typical data of relative peak intensities in +m/+m and db+/db+ mouse sera (upper, representative of 4–8 independent observations) and the peak intensity averages at m/z 4206 and 26100 (lower, n = 4 for +m/+m, n = 8 for db+/db+). The analyzed peak is indicated by arrows in the data of mass spectral signals. **P < 0.01; significantly different from the peak in wild-type mice, by unpaired t -test.

Journal: BMC Pharmacology

Article Title: Effect of green tea on blood glucose levels and serum proteomic patterns in diabetic (db/db) mice and on glucose metabolism in healthy humans

doi: 10.1186/1471-2210-4-18

Figure Lengend Snippet: Proteomic analyses demonstrating the differences in protein profiles of sera from diabetic and wild-type mice. Serum samples from fasting diabetic (db+/db+) mice and fasting wild-type (+m/+m) mice were loaded onto ProteinChip arrays. (A) List of peaks of proteins and/or peptides with indicated m/z values, the peak intensities of which were significantly changed in the diabetic state. Relative peak intensities were averaged (n = 8). The fold changes are presented as ratios of the peak intensities at indicated m/z values in db+/db+ to those in the +m/+m mice. Peaks at m/z 4203, 4576, 8515, 9291, 17406 and 18678 were obtained using CM10 ProteinChip (pH4). Peaks at 8733 and 9311 m/z were obtained using CM10 ProteinChip (pH7). Peaks at m/z 3933, 4119, 4206, 4369, 4566, 4579, 4637, 8523, 8827, 8915, 9283, 13075, 17407, 17418, 17622, 18431, 18691, 22334 and 26100 were obtained using Q10 ProteinChip. Peak at m/z 4211 was obtained using IMAC30. The chips were analyzed by SELDI-TOF-MS. (B) and (C) Typical data of relative peak intensities in +m/+m and db+/db+ mouse sera (upper, representative of 4–8 independent observations) and the peak intensity averages at m/z 4206 and 26100 (lower, n = 4 for +m/+m, n = 8 for db+/db+). The analyzed peak is indicated by arrows in the data of mass spectral signals. **P < 0.01; significantly different from the peak in wild-type mice, by unpaired t -test.

Article Snippet: Several types of ProteinChip Array, i.e., Q10 (an anionic exchanger, pH8), CM10 (a cationic exchanger, pH4 and pH7) and IMAC30-Cu 2+ (immobilized metal affinity chromatography, pH7) (Ciphergen Biosystems), were used to fractionate proteins in serum.

Techniques:

Changes in serum protein profiles in db+/db+ mice by administration of green tea. Serum samples from fasting diabetic (db+/db+) mice 2 h after administration of green tea suspension were loaded onto ProteinChip Arrays. The chips were analyzed using SELDI-TOF-MS. (A) List of peaks of proteins and/or peptides with indicated m/z values, the peak intensities of which were significantly changed by the green tea administration. Relative peak intensities were averaged (n = 4). The fold changes are presented as ratios of the peak intensities at indicated m/z values 2 h after to before green tea administration. Peaks at m/z 7495, 7595, 7808, 7920, 14983, 15612 and 15614 were obtained using CM10 ProteinChip (pH4), whereas those at m/z 7503, 7611, 7823, 7926, 11651, 11664, 11863, 15004 and 15638 were obtained using CM10 ProteinChip (pH7). Peaks at m/z 4212, 4226, 7499, 11637, 11846, 13711, 13831, 14974, 15180, 31204 and 65906 were obtained using IMAC30 ProteinChip. (B) Typical data of relative peak intensities (upper, representative of 4 independent observations) and the peak intensity average at m/z 11863 (lower, n = 4) after green tea administration and saline control. The analyzed peak is indicated by arrows in the data of mass spectral signals. **P < 0.01; significantly different from the peak obtained before the administration, by unpaired t -test.

Journal: BMC Pharmacology

Article Title: Effect of green tea on blood glucose levels and serum proteomic patterns in diabetic (db/db) mice and on glucose metabolism in healthy humans

doi: 10.1186/1471-2210-4-18

Figure Lengend Snippet: Changes in serum protein profiles in db+/db+ mice by administration of green tea. Serum samples from fasting diabetic (db+/db+) mice 2 h after administration of green tea suspension were loaded onto ProteinChip Arrays. The chips were analyzed using SELDI-TOF-MS. (A) List of peaks of proteins and/or peptides with indicated m/z values, the peak intensities of which were significantly changed by the green tea administration. Relative peak intensities were averaged (n = 4). The fold changes are presented as ratios of the peak intensities at indicated m/z values 2 h after to before green tea administration. Peaks at m/z 7495, 7595, 7808, 7920, 14983, 15612 and 15614 were obtained using CM10 ProteinChip (pH4), whereas those at m/z 7503, 7611, 7823, 7926, 11651, 11664, 11863, 15004 and 15638 were obtained using CM10 ProteinChip (pH7). Peaks at m/z 4212, 4226, 7499, 11637, 11846, 13711, 13831, 14974, 15180, 31204 and 65906 were obtained using IMAC30 ProteinChip. (B) Typical data of relative peak intensities (upper, representative of 4 independent observations) and the peak intensity average at m/z 11863 (lower, n = 4) after green tea administration and saline control. The analyzed peak is indicated by arrows in the data of mass spectral signals. **P < 0.01; significantly different from the peak obtained before the administration, by unpaired t -test.

Article Snippet: Several types of ProteinChip Array, i.e., Q10 (an anionic exchanger, pH8), CM10 (a cationic exchanger, pH4 and pH7) and IMAC30-Cu 2+ (immobilized metal affinity chromatography, pH7) (Ciphergen Biosystems), were used to fractionate proteins in serum.

Techniques: